[Jan 21, 2022] Get New H35-912 Practice Test Questions Answers
H35-912 Dumps and Exam Test Engine
NEW QUESTION 101
Regarding the MA5800 frame type equipment, the equipment installation environment quality standards, what are the correct statements? (Multiple Choice)
- A. The AC protection ground of the AC power supply should be reliably connected to the AC protection ground. The GND grounding and PGND grounding provided by the customer must be connected to the same grounding body.
- B. AC power supply related parameters are in line with the long-term safe operation of the equipment. The equipment room AC power system should have a lightning protection unit, and the lightning protection unit should be grounded reliably.
- C. No fire and anti-static measures are required in the equipment room.
- D. Customer's PGND cable, GND cable of primary power supply, wire diameter and power supply mode of a 48V cable to PDF or distribution box, subject to engineering design documents and company shipments, to meet equipment operation and capacity expansion requirements.
Answer: A,B,D
NEW QUESTION 102
For the lifting of the antenna, traction is required to prevent the antenna from colliding with the tower.
- A. True
- B. False
Answer: A
NEW QUESTION 103
If you are sitting in the back seat of the car, there is no need to wear a seat belt.
- A. True
- B. False
Answer: B
NEW QUESTION 104
When delivered, the recommended load control frame is placed at the bottom of the cabinet; the storage settings are placed at intervals of 1U (1U = 44.45 mm) to facilitate management and reduce vibration transmission.
- A. True
- B. False
Answer: B
NEW QUESTION 105
The AC protection ground of the AC power supply should be reliably connected to the AC protection ground. The GND ground and PGND grounding provided by the customer must be connected to the same grounding body.
- A. True
- B. False
Answer: A
NEW QUESTION 106
The traditional MSO access network is constituted by HUB room and waht parts, to be called HFC (Hybrid Fiber Coaxial) network? (Multiple Choice)
- A. Optical node
- B. Optical distribution network
- C. Optical line terminal
- D. Coaxial distribution network
Answer: A,D
NEW QUESTION 107
Which of the following is the work done during the verification phase after "high-risk operation"?
- A. Confirm the operation board
- B. Network test verification
- C. Recording of major operational records
- D. Confirmation of project operation completion
Answer: B
NEW QUESTION 108
The CH220/CH221 compute node performs IO expansion on the basis of the CH121 compute node and supports up to four PCIe cards in the full-width slot.
- A. True
- B. False
Answer: A
NEW QUESTION 109
How many hard disks does the RH8100 V3 Type A front IO module support?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: B
NEW QUESTION 110
About the requirements that OceanStor 18000 series high-end storage requirements for the environment, which is wrong?
- A. It is recommended to use a high efficiency filter to filter the air entering the air center of the data center.
- B. It is recommended to adopt the layout of hot and cold air duct isolation.
- C. There are certain requirements for vibration and shock
- D. Can work at various altitudes
Answer: D
NEW QUESTION 111
What scene does the light cat ONT belong to?
- A. FTTD
- B. FTTC
- C. FTTB
- D. FTTH
Answer: D
NEW QUESTION 112
Twisted copper wire is the household resource of MSO.
- A. True
- B. False
Answer: B
NEW QUESTION 113
For the convenience of staff C, use the mobile phone to take some training materials and project cases on the 3ms website for easy inquiry, not counting information security violations.
- A. True
- B. False
Answer: B
NEW QUESTION 114
Which is correct about the operation of live equipment and circuits?
- A. Operation of live equipment and circuits can only be carried out by personnel with relevant qualifications
- B. Everyone can operate live equipment and circuits as long as they are insulated.
- C. Powerful operation requires qualified personnel to perform, weak power does not need
Answer: A
NEW QUESTION 115
Which of the following statements about copper wire access are wrong? (Multiple choice)
- A. The equipment room distribution frame does not belong to the copper distribution network.
- B. The copper wire access consists of three parts: the central office access device, the copper wire distribution network and the user access terminal.
- C. The corridor distribution box belongs to the copper distribution network.
- D. Twisted Pair is a signal transmission cable made of two or more pure copper wires insulated from each other.
Answer: A,D
NEW QUESTION 116
In the equipment room where the bracket and anti-static floor are installed, the cable can be routed under the cable, and all cables are routed through the floor interlayer or the cable trough. If the upper cable is used, you need to lay a cable tray on the top of the cabinet. The cable is routed through the cable tray.
- A. True
- B. False
Answer: A
NEW QUESTION 117
......
2022 New PrepPDF H35-912 PDF Recently Updated Questions: https://www.preppdf.com/Huawei/H35-912-prepaway-exam-dumps.html